High-temperature cable manufacturing in Jiangsu, ChinaSpecification-based production · Export-ready supply
PRODUCT 02Orange insulated single-core wireStripped sample · construction view
Orange insulated single-core wire

An orange single-core sample with its stranded conductor exposed. The UL style and certification scope are checked against the wire marking and documentation.

Guofeng / Product 02

UL Style High-Temperature Wire

UL3071 / UL3074 / UL3075 / UL3122 · temperature−60°C to +200°C

Catalog voltage: 600 V for UL3071/3074/3075; 300 V for UL3122. Style listing is not proof of current certification.

The supplied product catalog includes multiple UL-style constructions covering a range of conductor, insulation and temperature requirements. The applicable style and current certification scope should be confirmed for each inquiry.

Selection reference
Exact UL style number
Construction options
Silicone / fluoropolymer / braided designs
Documentation
Style and certificate scope reviewed per model

Technical specification

Start with the essentials.

Selection reference
Exact UL style number
Construction options
Silicone / fluoropolymer / braided designs
Documentation
Style and certificate scope reviewed per model
Conductor size & diameter
Specify AWG or mm² and any finished-diameter limit.
Voltage & documentation
Match to the selected model, destination market and required test specification.
Order configuration
Colour, marking, cut length or reel length, quantity and packing.

Representative Catalog Data

Each row applies only to its named model, not every cable in this family.

ModelConstructionTemperatureVoltage
UL3239Tinned copper / silicone rubber insulation-60°C to +200°C3-50 kV options
UL1212Silver- or nickel-plated copper / PTFE insulationStyle-specificConfirm by construction

The family catalog is a reference, not an order-specific datasheet. Final ratings and dimensions belong on the confirmed model specification.

Inside the wire

Understand the construction.

01

Conductor

Silver-coloured strands are visible at the stripped end.

02

Insulation

The outer surface is smooth and orange.

03

Identification

The style number and wire marking identify the specification.

Material and construction options

Fluoropolymer optionsSilicone rubber optionsGlass-fibre braid optionsTinned or plated copper options

Typical applications

Match the cable to the equipment.

Appliance internal wiring

Start with the style specified on your drawing and the destination-market requirements.

Motors & electrical assemblies

Match conductor size, voltage, temperature and the required wire marking, not the style number alone.

Home appliancesLighting equipmentHeating productsMotors and transformersIndustrial control equipment

Product references

Models in this family

Have a model on your drawing? Choose it below to carry the reference into your inquiry. This does not confirm interchangeability or certification.

View the family catalog ↗

Model-by-model construction

Materials, layers and temperature.

Read from the conductor outward. Each specification belongs to the named model, not every product in this family.

UL3071 / UL3074 / UL3075 / UL3122

Temperature range−60°C to +200°C

Construction
Tinned copper conductor → silicone rubber insulation → fiberglass braid with silicone resin

Catalog voltage: 600 V for UL3071/3074/3075; 300 V for UL3122. Style listing is not proof of current certification.

Source: Feiyu catalog · page 28

Product questions

Before you choose.

Does a catalog style number prove current certification?

No. A style number identifies a construction reference. Current certificate scope and applicability to the ordered wire must be verified separately.

Can you review a replacement for another manufacturer's wire?

Provide the full marking, drawing and required approvals with the operating conditions. A proposed alternative needs technical review before substitution.

Samples & repeat orders

Keep the specification with the order.

01 / First order

Define the cable

Prepare the model or drawing, operating conditions, quantity and destination. Include required documents and your requested delivery date.

Prepare a new requirement ↗
02 / Sample request

Define what to check

Include the trial length and the dimensions or performance you need to evaluate. Sample availability, cost and timing are confirmed separately.

Prepare a sample request ↗
03 / Repeat order

Reference the approved version

Use the previous order, drawing revision or approved sample reference. State what stays the same and any changes in size, material, colour or packing.

Prepare a repeat-order request ↗

Your application

Prepare a clear requirement.

UL Style Wire will be selected in the inquiry worksheet. Download it to share with your sales contact; online sending is not available yet.

Prepare your inquiry ↗
  1. 01Requested UL style
  2. 02Conductor size
  3. 03Colour and printing
  4. 04Coil or reel length
  5. 05Target market and documentation

Compare related constructions

Looking for a different option?